Trotec LD6000 Combination Detector
Trotec LD6000 Combination Detector
- Acoustic and trace gas leak detection with only one device
- Innovative smart function for a still quicker precise leak detection (patent pending)
- Many typical cases of application already preassigned for quick access
- Pipe location mode
- Meets the requirements for BGV B3 (formerly VBG 121)
FIND YOUR TROTEC STOCKIST HERE:
Leak detection and acoustic pipe location
Whether for line routing, leak encircling or pinpoint location – the advanced LD6000 and high-quality microphones of German manufacturing enable the capturing, signal processing and display of even the teensiest leakage sounds in as yet unknown dimensions.
LD6000 – The ideal solution for the industry, utility companies and craft
With the LD6000, industrial users benefit from a universally applicable measuring instrument, which not only ensures quick and precise leak detection in wide supply networks, but by use of the hydrogen measurement method enables especially economic test methods, e.g. the tightness test of weld seams, valves, tanks, boilers, pressure lines or pump bodies.
The LD6000 provides manifold possible uses for utility companies’ water loss analyses: Acoustic pinpoint location with highly sensitive ground microphones, trace gas leak detection in drinking water systems, route detection on metallic and non-metallic pipelines – or tightness tests of pipe connections and seals. Comprehensive equipment accessories like the ground, contact and palpation probe microphones make the LD6000 also a universal solution for quick and reliable leak detection in craft applications.
The innovative LD6000 sets new standards in leak detection…
Acoustic pinpoint location
Pipework location
Long-term measurement with logging function
Trace gas detection
all with only one device!
Technical data | ||
---|---|---|
General information | ||
Article number | 3.110.008.010 | |
Sound | ||
Min. measuring range [Hz] | 0 | |
Max. measuring range [Hz] | 4,000 | |
Amplification [dB] | 120 | |
Input impedance [Ω] | 1 M | |
Max. output impedance [Ω] | 10 | |
Display | ||
LCD | ||
Touch | ||
Colour | ||
Memory organisation | ||
Memory | Internal flash memory for up to 20 measurement series and as buffer memory for recording long-term measurements of 5, 15, 30 and 60 min. | |
Storage type | Internal flash memory | |
Interfaces | ||
Bayonet (microphone) | ||
Bayonet (sensor) | ||
6.3 mm audio jack (headphones) | ||
Device control | ||
Membrane keyboard | ||
Control knobs | ||
Housing design | ||
Plastic/metal | ||
Type of protection | ||
IP54 | ||
Ambient conditions | ||
Operation - min. temperature [°C] | -5 | |
Operation - max. temperature [°C] | 55 | |
Operating time | ||
Up to 14 hours in continuous operation | ||
Up to 40 hours in normal usage | ||
Power supply | ||
Battery type | 4 x type LR14 C 1.5 V | |
Dimensions | ||
Length (packaging excluded) [mm] | 210 | |
Width (packaging excluded) [mm] | 160 | |
Height (packaging excluded) [mm] | 60 | |
Weight | ||
(packaging excluded) [kg] | 1.05 |